Karl Fischer Titrator Model : µAquaCal50

karl_fischer_titrator_modelaquacal
 Technical Specification: Method of Detection : Conductometric Backlit LCD Display : 20 x 4 Line Alphanumeric Range of Moisture Detection : less than 20 PPM to 100% Display of Reading : Direct Reading of Moisture in PPM, Percentage(%) & mg/ml of water Dispenser : Motorized Dispensing for ...Read more



  • Description

 Technical Specification:

  • Method of Detection : Conductometric
  • Backlit LCD Display : 20 x 4 Line Alphanumeric
  • Range of Moisture Detection : less than 20 PPM to 100%
  • Display of Reading : Direct Reading of Moisture in PPM, Percentage(%) & mg/ml of water
  • Dispenser : Motorized Dispensing for low and accurate measurement of reagent.
  • Electrode : Dual Platinum Electrode.
  • Stirring Time : 00:00 to 99:00 ( Minutes : Second ) - Users Adjustable
  • End Point Time : 1-99 Seconds , Users Adjustable
  • End Point Sensitivity of Moisture Detection : Users Adjustable
  • Calibration Reminder Alarm : 0-99 hours
  • Data Storage : More than 10 Analysis data with corresponding calibration data.
  • Interface : Parallel Port for Dot-matrix Printer attachment.
  • Input : Electrode Connector
  • Power supply : 230 VAC ±10%, 50 Hz

Salient Features:

  • Metalic Epoxy Based Powder Coated Body
  • Parallel Port to connect 80 column Dot-matrix Printer
  • Report Formation as per GLP Compliance
  • Built in Magnetic Stirrer with soft touch Key Speed Controller
  • Automatic end point detection with Audio Alarm
  • OVER TITER Audio Alarm save KF Reagent
  • Automatic Calculation of Avg. Factor and Maxi. 10 KF Factor can be stored in memory
  • Auto Neutralization reduces the time between analysis & Gives accurate Results
  • Onsite Dispenser Calibration/Validation Facility
  • MOC of Dispenser is SS/ABS/TEFLON for Corrosion Protection & Maintenance free Operation
  • In-Built Flushing System for cleaning dispensing path

Optional:

  • Auto Drain of Reaction Vessel
  • RS-232 to USB Interface with Cable & Driver software to Transfer Data from Inst. to PC
  • GMP model

Category