Karl Fischer Titrator Model : µAquaCal100

Brand: ANALAB INSTRUMENTSANALAB INSTRUMENTS
karl_fischer_titrator_modelaquacal_100
Technical Specification : Method of Detection : Conductometric Backlit LCD Display : 20 x 4 Line Alphanumeric Range of Moisture Detection : less than 10 PPM to 100% Display of Reading : Direct Reading of Moisture in PPM, Percentage(%) & mg/ml of water Dispenser : Motorized Dispensing for ...Read more



  • Description

Technical Specification :

  • Method of Detection : Conductometric
  • Backlit LCD Display : 20 x 4 Line Alphanumeric
  • Range of Moisture Detection : less than 10 PPM to 100%
  • Display of Reading : Direct Reading of Moisture in PPM, Percentage(%) & mg/ml of water
  • Dispenser : Motorized Dispensing for low and accurate measurement of reagent.
  • Electrode : Dual Platinum Electrode.
  • Interface : Serial & Parallel Port for PC & Dot-matrix Printer attachment.
  • Stirring Time : 00:00 to 99:00 ( Minutes: Second ) - Users Adjustable
  • End Point Time : 1-99 Seconds , Users Adjustable
  • End Point Sensitivity of Moisture Detection : Users Adjustable
  • Calibration Reminder Alarm : 0-99 hours
  • Data Storage : More than 100 Analysis data with corresponding calibration data.
  • Input : Electrode Connector
  • Power supply : 230 VAC ± 10%, 50 Hz

Salient Features :

  • Metallic Epoxy Based Powder Coated Body
  • Parallel & Serial Port for Dot-matrix Printer & PC attachment respectively.
  • Report Formation as per GLP Compliance.
  • 100 analysis data storage with corresponding calibration date with Batch Number,
  • Real Date & Time, Operator Name, Sample Name, searching of data as per Batch No.
  • Built in Magnetic Stirrer with soft touch Key Speed Controller.
  • Automatic end point detection with Audio & Visual Alarm.
  • Auto Neutralization reduces the time between analysis & gives accurate Results.
  • OVER TITER Audio Alarm save KF Reagent
  • Automatic Calculation of Avg. Factor &10 KF Factor can be stored in memory
  • Auto Drain Facility for cleaning reaction vessel.
  • Onsite Dispenser Calibration / Validation Facility.
  • MOC of Dispenser is SS/ABS/TEFLON for Corrosion Protection & Maintenance
  • Free Operation.
  • In-Built Flushing System for cleaning dispensing path.
  • Users adjustable end point sensitivity.
  • Calculation of % RSD
  • Transfer of weight directly from Balance to KF Unit.
  • RS-232 to USB interface with Cable & Driver Software to Transfer Data from Inst. to PC
Brand: ANALAB INSTRUMENTSANALAB INSTRUMENTS