304 Stainless Steel Operation Plat form and Internal Wall
- Stainless steel operation platform without screws, no accumulation of contaminant
- Dismountable air in-flow plate, easy to clean and disinfect
- Internal wall is constructed by a single plate, and the12mm arc angle conner leaves no cleaning blind area
- The volume of liquid tank is over 4L, equipped with outlet valve for convenient cleaning and maintaining
- Concaved operation platform, waste liquid easily collected
- Adjustable supporter (0-75mm) without exposed screw thread, preventing the germs from multiplying
Ultra Low Penetration Air Filtration System
- American AAF ULPA filter
- Tested to a typical efficiency of 99.9995% for 0.12 micron particles
- Provides FED STD 209E class 1 (or ISO14644.1 class 3) clean air to work surface in a stable vertical laminar flow to protect samples
- The exhaust ULPA filter traps biohazard particles acquired from the work surface before air is exhausted to the room, offering personnel and environmental protection
High Efficiency Blower System
- The blower system is designed for high performance operation, maximum energy efficiency and minimal maintenance
- Self cooling system reduces energy consumption while enhancing reliability
Digital Microprocessor Control System
- LCD display
- Real-time display of key parameters: downflow velocity, inflow velocity, airflow volume, static pressure, negative pressure, accumulative running time of fan and UV lamp, left lifetime of filter
- Sound & light alarming function
- UV sterilization reservation setting function
- Time setting function
Ergonomic Design
- The 10° angled viewing window improves comport and alleviates fatigue of operator
- 75mm adjustable supporter ensures correct height for different users
- UV sterilization reservation function
- Lamp is set behind supporter, making eyes more comfortable
- Automatically remind when filter lifetime less than 10% , so that filter can be changed in time
- Removable stainless steel work surface makes convenient cleaning
- Draining valve is easy to clean and maintain
Interlock Safety Protection
- Glass sash and the blower/motor interlocking
- Fluorescent light & UV light
- UV light, blower/motor and fluorescent light interlocking
- Sash and fluorescent light interlocking
Intelligence alarm system
- Alarm when opening height of sash exceeds the safety limit line
- Alarm when airflow fluctuation exceeds 20%
- Alarm when sash is not closed properly but blower turned off
- Alarm when filter life is less than 10% of total lifetime
Type
|
Class II, Type A2
|
Working Voltage and Frequency
|
220V±10%,50±1 Hz
|
Power (VA)
|
1300
|
Power of Blower(W)
|
350
|
Airflow Circulation
|
220/50
|
Main Filter Typical Efficiency
|
ULPA,99.9995%@0.12μm
|
Exhaust Filter Typical Efficiency
|
HEPA,99.995%@0.3μm
|
Downflow Velocity(m/s)
|
0.28
|
Inflow Velocity(m/s)
|
0.55
|
Fluorescent Lamp Intensity(Lux)
|
≥1100
|
Net/Gross Weight
|
258/293(kg) 568.8/646.0(lbs)
|
Internal Dimensions(W*D*H)
|
1167*610*680(mm) 45.9*24.0*26.8(in)
|
External Dimensions(W*D*H)
|
1360*780*2200(mm) 53.5*30.7*86.6(in)
|
Packing Dimensions(W*D*H)
|
1490*910*2180(mm) 58.7*35.8*85.8(in)
|
Supporter
|
75mm adjustable height
|
Container loads (20'/40'/40'H)
|
7/16/16
|
Alarm
|
Sound and Flash
|
Certificate
|
SFDA EN12469 CE ISO 13485 : 2003
|