EQUITRON Advantages:
- Square Designed with inbuilt Documentation Device.
- Inbuilt recipes (8 Nos.), (wrapped load, unwrapped load, glass load, Bowie-Dick Test, Vacuum Leak Test, Media 115, Garment & User-defined).
- Calibration reminders.
- Power failure restore facility.
- Automatic Water filling facility, Provision of free Steaming & option Drain Cooling function.
- Inbuilt Steam Generator.
- Positive Pulsing (Avoids Lag Time in Aqueous Loads) & Negative Pulsing (Vacuum cycles), Vacuum Drying (No Condensation water droplets post Sterilization thus eliminates the need of Oven).
- User settable alphanumeric batch number and operator name.
- Electric on/off safety switch. Saves Power bills by 20-30%
Construction:
The SLV range, like all EQUITRON Autoclaves, is designed for ease of use and dependability and is manufactured under strict supervision. Each & every chamber is hydrostatically tested as per standards. Rigorous inspection standards and traceable calibration reports ensure dependable performance
- Internal chamber and lid along with all wetted parts fabricated from Stainless Steel.
- Internal steam generator for steam on demand
- Single lever pronged closure system with a patented Silicone Gasket.
- Easy lift and closing of the lid assisted support.
- PU Castors for ease of movement.
- Modular panel design-for easy access to all critical components.
- Built-in validation port enables user for self- calibration checks.
- Two independent gauges for steam generator & chamber.
- Manual release valve with a 0.2µ filter to normalise chamber pressure at the end of cycle – with sterile air.
Control Systems:
At the heart of EQUITRON SLV is a Programmable Logic Controller (PLC) with 3.5” touch screen colour display which provides for a flexible user friendly interface and accurate control.
All the critical parameters including set parameters and alarms are displayed on the touch screen. The PLC controls and monitors each and every parameter which provides higher reliability.
- Selection of pre-set cycles from cycle library
- Pre-set Bowie Dick Test
- User customisable cycle with flexibility of setting following parameters:
- Number of negative pulses
- Number of positive pulses
- Sterilization temperature
- Sterilization hold time
- Vacuum drying
- Corrective action program on power failure.
Safety:
- Every single Autoclave chamber is hydraulically tested to twice its operating pressure. Inspection as per set standards –right from the raw material inward stage, to in process inspections to final tests and calibrations is conducted by qualified Engineers.
- Spring loaded safety valves for steam generator and chamber.
- Pressure Switch for over pressure detection in steam generator
- Pressure interlock on door.
- Door interlock for cycle start.
- Audio & visual alarms for:
- Low Water
- Over Temperature
- Over Pressure
- MCB for electrical safety
In-Built Online Printing Facility:
- Display of five channels – 4 temperature plus one pressure.
- Print to external DMP LX-300+ (part of standard supply) with date, time, set point, reading of 4 temperature sensors & pressure.
- Print of process status with each print.
- Print of F0 value for sensor A.
- Print interval user settable 15 – 600 seconds.
Model
|
Working Chamber Size (Ø x D) mm / Capacity L
|
Carrier (Ø x D) mm
|
Heater
|
#7441SLVSG
|
Ø 450 x 710 / 113
|
2 x Ø 400 x 330
|
7 kW
|
#7451SLVSG
|
Ø 550 x 760 / 180
|
2 x Ø 500 x 350
|
10 kW
|